PLAZA PAVER™ SPECIFICATIONS - CLASSIC SERIES

Plaza Paver Physical Properties

Compressive Strength 8000 psi (min.) ASTM Test Method C140
Water Absorption 5% max. ASTM Test Method C140
Flexural Strength 725 psi ASTM Test Method C293
Freeze Thaw 1% loss of dry weight ASTM Test Method C67

Plaza Paver Features

Size Available 24" x 24" x 1-7/8" (nominal) and 17 3/4" x 1-7/8" (nominal)
Dimensional Tolerance +/- 1/16" (length, width, height, convex, concave)
Weight 21 lbs/sq. ft.

Plaza Paver II Physical Properties and Features

Weight Compressive Strength Size Color Texture
20.4 lbs./sq. ft. 6500 psi 16" x 16" x 1'-3/4" Natural Smooth